Meter & Probe worked guide

Estimate the effect of a voltmeter on a high impedance source

If a sensor node falls from an expected 5 V to about 4.55 V when you connect a meter, the meter may be part of the explanation. A 10 MΩ input is a load, even when its display has plenty of digits.

Content reviewed · Examples are calculations, not tests of a supplied instrument.

Model the source as a voltage plus a resistance

For a steady DC signal, use the source’s equivalent resistance and the meter input resistance on the exact function and range. In a simple linear model, Vind = Vopen × Rin ÷ (Rsource + Rin). Use the manual for the input resistance; it can depend on function, range or mode. Cable leakage and capacitance can matter elsewhere, especially for changing signals.

Two 1 MΩ resistors across an ideal 10 V supply have a 5 V midpoint and a 0.5 MΩ equivalent source resistance. A 10 MΩ voltmeter lowers the calculated midpoint to about 4.762 V. Use the divider's equivalent resistance, not simply one resistor's value.

Red and black multimeter probes connected securely to a real breadboard circuit.
Red and black multimeter probes connected securely to a real breadboard circuit.Real photograph · illustrative context, not a Meter & Probe test. Zeroping / Wikimedia Commons · CC BY 4.0 · resized and letterboxed for web

Two bench examples with the same meter

With an ideal open-circuit 5.00 V source, a 1.00 MΩ source resistance and a 10.0 MΩ input, the connected voltage is about 4.55 V, roughly 9.1% below unloaded. Reduce the source resistance to 10 kΩ and the same meter sees approximately 4.995 V. The display counts did not change; the interaction with the circuit changed.

A larger input resistance reduces this effect. A low impedance mode deliberately loads a circuit more and must not be treated as a higher accuracy version of the normal mode. Use a suitable input or buffer only within its own verified conditions; do not use this calculation to choose equipment for live electrical testing.

Separate two effects in the measurement record

List the estimated loading and the display error as separate lines. To read a named meter’s numerical specification, see the UT139C DC voltage example.

A small Wi-Fi module wired to a breadboard.
The source and meter form a circuit together.RetroEditor / Wikimedia Commons · CC BY-SA 4.0 · resized for web

Sources and review

Reviewed . Numerical examples are calculations or illustrations.

Common questions

Is a high-input-impedance meter worth buying for a sensor circuit?

Compare the meter input resistance with the source resistance. A high-impedance source can change when connected to a conventional meter; check the specific mode before buying.

Free online measurement tools

Free tools for interpreting a loaded voltage

Use the free reading checker when connecting a meter changes the symptom. An accuracy interval describes the instrument limit; it cannot correct source loading without a separate circuit model.

No sign-up. No subscription. All eight tools are free to use.

Browse all free multimeter tools →

Practical questions

Questions about voltmeter input loading

Why can a voltmeter lower the voltage at a high-resistance node?

The input resistance forms a divider with the source resistance. The measured circuit is therefore different from the unloaded source model.

Link to this answer
How do I estimate voltage loading from meter input resistance?

For a resistive source model, multiply open-circuit voltage by meter resistance divided by the sum of source and meter resistances.

Link to this answer
What fraction of source voltage does a 10 MΩ meter show behind 1 MΩ?

The ideal divider ratio is 10/11, approximately 90.9%. This illustrates loading and does not describe every real source or input function.

Link to this answer
Can extra display digits correct a high-impedance loading error?

More digits do not remove the load presented by the input. Assess input resistance and the source model before interpreting added resolution.

Link to this answer
Does every function on a multimeter have the same input impedance?

Check the manual for the selected function and range. Different input modes, including low-impedance functions, can load a source differently.

Link to this answer
Why might two meters change a divider voltage by different amounts?

Their input impedances and conditions can differ. Each meter becomes part of the divider, so the circuit may not present the same voltage to both.

Link to this answer
Will connecting two voltmeters simultaneously remove the loading problem?

The inputs add another combined load. Simultaneous measurement can change the node further, so include the complete connection in the model.

Link to this answer
Is input loading the same issue as an open-probe floating voltage?

Loading concerns the interaction with a source. A floating input lacks a defined measurement reference; it requires a different initial check.

Link to this answer
When is the simple source-resistance divider model insufficient?

Frequency dependence, capacitance, active source behaviour and time variation can matter. Use the model only within the conditions it represents.

Link to this answer
Which setup details help explain a voltage that changes when measured?

Record source impedance, meter input mode, connection points and settling behaviour. Keep the unloaded assumption separate from the loaded indication.

Link to this answer
How much current does a 10 MΩ voltmeter draw at 5 V?

In the simple resistive model, I = V/R gives 0.5 µA. That is negligible for some sources and a significant load for others.

Link to this answer
What input resistance keeps resistive loading below 1%?

For the simple divider model, Rin must exceed 99 times the source resistance. This addresses loading only, not the meter's other errors.

Link to this answer
Why does a 1 MΩ plus 1 MΩ divider have 0.5 MΩ source resistance?

For its small-signal equivalent with an ideal supply, the two resistors appear in parallel at the midpoint. Their parallel value is 0.5 MΩ.

Link to this answer
Can I correct a loaded reading if I know both resistances?

For a valid linear DC model, Vopen = Vind × (Rsource + Rin)/Rin. Uncertain resistances and non-linear behaviour limit how useful that correction is.

Link to this answer
Why does my divider voltage fall further when I connect a scope too?

The scope and meter inputs load the node in parallel. Probe capacitance also affects changing signals, so the combined setup needs its own model.

Link to this answer
Does a 10× scope probe always have a 10 MΩ input?

Check the probe and scope combination. Its resistance, capacitance, attenuation and bandwidth depend on the actual equipment and settings.

Link to this answer
Can a voltage follower buffer solve every high-impedance measurement?

A suitable buffer can reduce loading, but input bias current, offset, supply headroom and stability matter. It introduces specifications that need checking too.

Link to this answer
Why does a pH electrode need more care than a bench supply output?

An electrode can have very high source impedance. A conventional meter may draw enough current to alter the voltage; use an appropriate interface and method.

Link to this answer
Will a meter's LoZ mode help measure a weak sensor output accurately?

LoZ deliberately increases loading. It can collapse a weak signal rather than reveal its unloaded value, so it is not a general sensor-measurement upgrade.

Link to this answer
Can damp or dirty connectors affect a high-impedance reading?

Leakage paths can become comparable to the source or input resistance. Contamination that barely matters on a low-resistance supply can matter greatly here.

Link to this answer
Why does the voltage take time to settle after a probe is attached?

Source resistance and input or cable capacitance form a time-dependent network. A settling transient is different from a steady loading error.

Link to this answer
Is meter input resistance always constant when I change voltage ranges?

Not necessarily. Some designs change input resistance between ranges or modes. Use the exact function specification when predicting loading.

Link to this answer
Can input capacitance matter when the DC resistance is very high?

Yes. Its impedance falls with frequency, so a high-resistance input can still load fast edges or alternating signals appreciably.

Link to this answer
Why is a battery reading less affected than a high-value divider reading?

Their source impedances differ. Under the simple model, the same voltmeter produces much less voltage loss from a source with low equivalent resistance.

Link to this answer
What should I ask when a circuit behaves differently with a probe connected?

Name the node, its estimated source impedance, probe input, supply state and observed change. Ask whether resistance, capacitance or an added reference path explains it.

Link to this answer
Public discussions behind these questions

These discussions helped identify practical questions. The answers and calculated examples here are our own; technical references are listed in the article. Forum replies can disagree and are not product tests or safety certification.

Questions also include related situations inferred from the article. They are not measured search-frequency data.